Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-7 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	33
Date	08/07/14
Start Time	16:04:47
Diameter Midpoint
 11.3	797045
 11.8	881482
 12.2	847590
 12.6	852844
 13.1	871327
 13.6	871086
 14.1	882420
 14.6	872128
 15.1	863676
 15.7	853040
 16.3	834629
 16.8	804809
 17.5	764687
 18.1	721283
 18.8	681604
 19.5	620831
 20.2	554169
 20.9	492601
 21.7	433594
 22.5	368304
 23.3	310622
 24.1	252415
 25.0	203693
 25.9	160948
 26.9	122115
 27.9	89557.3
 28.9	64639
 30.0	44646.4
 31.1	29828.6
 32.2	18931.2
 33.4	11932.8
 34.6	7841.39
 35.9	4865.79
 37.2	2602.94
 38.5	1662.84
 40.0	1121.64
 41.4	849.694
 42.9	544.311
 44.5	480.314
 46.1	296.292
 47.8	293.15
 49.6	214.244
 51.4	178.333
 53.3	180.552
 55.2	116.643
 57.3	85.8036
 59.4	102.7
 61.5	97.4741
 63.8	86.3279
 66.1	94.656
 68.5	89.5394
 71.0	80.5928
 73.7	62.0586
 76.4	56.66
 79.1	78.0951
 82.0	54.919
 85.1	46.6145
 88.2	73.3695
 91.4	66.8522
 94.7	66.5864
 98.2	42.453
101.8	39.8527
105.5	42.0085
109.4	49.739
113.4	51.218
117.6	43.2379
121.9	40.1184
126.3	56.8503
131.0	42.3867
135.8	39.0506
140.7	44.1661
145.9	29.8848
151.2	34.4411
156.8	49.97
162.5	33.9211
168.5	30.093
174.7	24.2899
181.1	27.0484
187.7	32.3778
194.6	24.3707
201.7	28.7995
209.1	20.3164
216.7	23.124
224.7	11.5198
232.9	17.571
241.4	19.683
250.3	12.1229
259.5	16.9289
269.0	12.2082
278.8	12.1491
289.0	7.99357
299.6	6.80798
310.6	12.1793
322.0	13.1268
333.8	14.0757
346.0	10.4524
358.7	11.403
371.8	12.5516
385.4	7.22136
399.5	8.53049
414.2	9.03467
429.4	7.2372
445.1	2.37927
461.4	6.06834
478.3	13.6163
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.6925
High Voltage	9931.01
Lower Size(nm)	11.1397
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1084.4
Median(nm)	15.6408
Mean(nm)	16.51
Geo. Mean(nm)	16.0355
Mode(nm)	14.0746
Geo. Std. Dev.	1.26546
Total Concentration(#/cm)	1.6202e+007
Comment	